AC60 series power supply is the one that change the electric supply into the required voltage and frequency through power converting circuit.Its main characteristic is to supply pure and stable sine wave power output,low harmonic distortion,high-stability frequency and regulation.It can impersonate many of the world of frequency voltage and output characteristics,and cover the whole industry needs,entirely consistent with the design engineer in research and production and testing of the product testing and life, and a simulated tests to a low, import equipment and the production of electricity and other applications.In addition, it will also support the air space and military equipment 400Hz.
1. High reliability
The main components are imported components, original
Mitsubishi IGBT inverter module, drive protection for the original Mitsubishi
movement, a perfect drive protection circuit to ensure reliable IGBT work.
2. Dynamic response speed (patented technology)
The use of double closed-loop feedback circuit, the inner
current loop to ensure that the nonlinear load waveform distortion; outer ring
voltage ring to ensure sudden increase in load pressure drop <1%, the
reaction rate is less than 2mS, the control circuit for analog circuits,
anti-interference ability, , Some manufacturers use the digital control
sampling required by the A / D conversion, calculation, D / A conversion,
control process is long, slow response, poor anti-jamming capability and easy
to crash.
3. Three-phase power supply can adapt to any unbalanced
load
Three-phase power supply can be three-phase system, but
also single-phase sub-tune. Three-phase power supply main circuit and control
circuit in accordance with the three sets of independent single-phase power
supply design. The main circuit is composed of a rectifier, a DC filter, an
inverter, an AC filter and a transformer. Three sets of single-phase inverter
circuit output mutual difference 120 angle, independent of each other in the
transformer primary side, connected to the transformer secondary star, the
output of the required three-phase AC. Voltage and waveform control For
single-phase output, three independent single-phase controllers are used so
that any phase of a three-phase power supply can be used as a single-phase
power supply independently and can accommodate any unbalanced load, resulting
in a significant increase The power of the load adaptability. Really do a load
imbalance.
4. Man-machine interface is good, table source one, high
accuracy
Voltage, frequency, current, power / power factor four
window measurement display, accuracy of 0.5, the source table integration.
5. Great load capacity
Power components of reasonable application, can withstand
3 times the rated current, and will not cause pressure drop.
6. Excellent stability
Frequency stability ≤ 0.01%, load stability ≤ 1%, the
output frequency of oscillation generated by the quartz oscillator, it is very
stable and accurate.
Model |
11005 |
11010 |
11030 |
11050 |
11100 |
31150 |
31200 |
313000 |
31450 |
311000 |
||||
Capacity(VA) |
500 |
1K |
3K |
5K |
10K |
15K |
20K |
30K |
45K |
100K |
||||
Output limit currency |
LOW(A) |
4.2 |
8.4 |
24 |
42 |
84 |
126 |
168 |
250 |
375 |
840 |
|||
HIGH(A) |
2.1 |
4.2 |
12 |
21 |
42 |
63 |
84 |
125 |
188 |
420 |
||||
Circuit model |
IGBT/SPWM pulse width adjustment mode |
|||||||||||||
Output frequency |
50Hz/60Hz 45-65Hz |
|||||||||||||
Load stability |
≤±1% |
|||||||||||||
frequency stability |
fixed-frequency≤±0.01%,frequency modulation≤±0.1% |
|||||||||||||
Input voltage |
220V±10% |
380V±10% |
||||||||||||
Phase |
single phase |
three phase four wire |
||||||||||||
Wave distortion |
≤3% |
|||||||||||||
Output voltage |
low-grade:0-150V continuous-tuning; high-grade:0 - 300 V continuous-tuning |
|||||||||||||
Reaction time |
≤2mS |
|||||||||||||
frequency meter |
0.1Hz |
|||||||||||||
Voltage meter |
0.1V |
|||||||||||||
Current meter |
0. 1A |
|||||||||||||
Power meter |
0.1W |
|||||||||||||
Ammeter display |
Frequency, voltage, current, power or PF 4 number display |
|||||||||||||
Protection function |
over voltage, over current, over temperature, over load, short circuit, and automatic alarm |
|||||||||||||
Insulation reactance |
500Vdc 20MΩ |
|||||||||||||
Pressure endurance insulation |
1500Vac/5mA/1min |
|||||||||||||
Cooling model |
Compulsive fan cooling |
|||||||||||||
Working temperature |
-10℃-45℃ |
|||||||||||||
Relative humidity |
0-90%(No condensing) |
|||||||||||||
Altitude |
1500meters |
|||||||||||||
Dimension (W×L×H)mm |
410*440*135 |
460*440*220 |
560*350*600 |
660*400*700 |
830*450*1100 |
1160*520*1370 |
Model
13060
13100
33150
33300
331000
332000
333000
334500
336000
338000
Capacity(KVA)
6
10
15
30
100
200
300
450
600
800
Output limit currency
LOW(A)
16.8
27.6
41.6
84
276
none
HIGH(A)
8.4
13.8
20.8
42
138
260
400
600
800
1050
Pulse